Frequency range
0.1mHz to 10MHz / 15MHz
|
|
|
|
|
From ultra low frequency to high
frequency.
High density measurements of up to 20,000 points at one
sweep are possible.
Logarithmic equal interval setting and auto-magnification in
sections where values greatly change are possible.
Resolution is 0.1mHz.
FRA5087
:
|
0.1mH to 10MHz
|
Higher than the
conventional 2.2MHz model!
|
FRA5097
:
|
0.1mH to 15MHz |
|
|
|
Gain accuracy :
±0.05
dB , Phase accuracy :
±0.3° |
|
|
|
|
Digital Fourier transforms
and a self calibration function assure that measurements
will always
be highly accurate. |
|
Dynamic range :
140dB |
|
|
|
|
Auto ranging which optimizes the
measurement
range at every measurement point and a high resolution A/D
converter
secure a wider dynamic range. Measurement is secured if a
great change
occurs during measurement. |
|
Isolation |
|
|
|
|
Oscillator output 2-channel and
analysis inputs are isolated from the cabinet by 250Vrms. In
this way, the instrument can be protected from damage by an
erroneous signal connection. |
|
Auto ranging
|
|
|
|
|
Input range is switched
automatically according to the input signal level, so setup
of voltage sensitivity is not necessary for the frequency
response analyzer. |
|
Various graphic
outputs |
|
|
|
|
Bode, Nyquist, Nicols, and Cole-Cole
plots can be displayed. Following measurement,
interconversion is also available. |
|
Impedance display
function(optional for
FRA5087) |
|
|
|
|
Impedance can be accurately
measured and displayed. Moreover, open-short correction,
maximum and minimum value displays, and screen image storage
can be done.
FRA5087
:
|
Optional
(PA-001-1231) |
FRA5097
:
|
Standard |
|
|
Excellent
functions are built-in
|
|
|
|
|
|
Basic Setup Key |
A basic setup screen is displayed simply by pressing the
basic setup key. The upper lower limits, amplitude, and
number of integrations for measuring frequency (sweep) can
be set on one screen. The conventional model's nuisance of
setting each item by switching the screen can thus be
avoided.
|
|
Battery backup
|
|
|
|
|
The contents of the setup and
measured data stored in the memory before turning off power
are held if power is turned off. |
|
GPIB and USB
equipped |
|
|
|
|
Measuring conditions can be set via
an external personal computer and measured data can be read
out to it via GPIB and USB. |
|
Easy saving and
reading by USB memory
|
|
|
|
|
|
USB |
Measured data can be stored and loaded into a USB memory
device. Furthermore, the following functions are
available.
|
SCREEN COPY |
A screen can be output to the USB memory and printer by the
press of a key.
|
CONDITION |
Setup conditions can be saved into and loaded from the USB
memory by the press of a key.
|
|
File read out
software |
|
|
|
|
Built-in
printer |
|
|
|
|
A printer for outputting hard
copies of on-screen images onto thermosensitive paper is
built-in, which makes saving measurements and creating
reports convenient. |
|
Color TFT LCD
|
|
|
|
|
A frequency response graph and setup
menu for measuring conditions can be displayed on a crisp
color LCD. |
|