NF LP6016-01 VI Tree.vi

Displays all Labview drivers for LP6016-01.


Connector Pane

NF LP6016-01 VI Tree.vi


Front Panel

NF LP6016-01 VI Tree.vi


Controls and Indicators


Block Diagram

NF LP6016-01 VI Tree.vi


NF LP6016-01 GettingStarted.vi

This VI at first sets basic parameters of LP6016-01 and turns on/off its voltage outputs.

After that, this VI reads setting parameters of LP6016-01 such as voltage settings parameters.

When output voltages are on , voltage setting mode ,output mode ,and limit voltage can not be set and setting of these parameters are skipped.


Connector Pane

NF LP6016-01 GettingStarted.vi


Front Panel

NF LP6016-01 GettingStarted.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

VISA resource name specifies the resource to be opened. The VISA resource name control also specifies the session and class.

cbool

[RS-232 enable]

Enables RS-232 parameters.

ON : Enables RS-232 parameters.

OFF : Chooses an interface other than RS-232.

cbool

Close?[Close]

Choose whether to close process of the interface.

ON : Closes process of the interface.

OFF : Do not close process of the interface.

ccclst

[Set]

Set parameters

cerrcodeclst

error in [Error In ]

The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.

cnclst

RS-232 param

Settings for RS-232 remote control.

ierrcodeclst

Error Out[Error Out]

The error out cluster passes error or warning information out of a VI to be used by other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.

ivsrn

CopyVISAsession[CopyVISAsession]

Displays VISA resource name that specifies the resource to be opened.

icclst

[Query]

Query setting parameters


Block Diagram

NF LP6016-01 GettingStarted.vi

NF LP6016-01 GettingStarted.vi

NF LP6016-01 GettingStarted.vi

NF LP6016-01 GettingStarted.vi

NF LP6016-01 GettingStarted.vi


NF LP6016-01 dvr_OUT.vi

Sets and queries the output voltage


Connector Pane

NF LP6016-01 dvr_OUT.vi


Front Panel

NF LP6016-01 dvr_OUT.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

VISA resource name specifies the resource to be opened. The VISA resource name control also specifies the session and class.

cbool

[Read]

Select the read or write VISA function.

True : Read

False : Write

cbool

[Set Voltage output]

<Voltage ON/OFF>

OFF : OFF

ON : ON

cbool

Output

Select the voltage output.

True : + Voltage output

False : - Voltage output

cerrcodeclst

Error IN[Error IN]

The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.

cu16

Terminator

Select terminator for RS-232 remote control to match the instument's terminator.

Select terminator "LF" for USB and LAN remote control.

0 : LF (Line Feed)

1 : CR (Carriage Return)

ivsrn

CopyVISAsession[CopyVISAsession]

Displays VISA resource name that specifies the resource to be opened.

ibool

[Query Voltage output]

Displays the state received from the device

ierrcodeclst

Error OUT[Error OUT]

The error out cluster passes error or warning information out of a VI to be used by other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.


Block Diagram

NF LP6016-01 dvr_OUT.vi

NF LP6016-01 dvr_OUT.vi

NF LP6016-01 dvr_OUT.vi

NF LP6016-01 dvr_OUT.vi


NF LP6016-01 dvr_LMV.vi

Sets and queries the limit voltage.


Connector Pane

NF LP6016-01 dvr_LMV.vi


Front Panel

NF LP6016-01 dvr_LMV.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

VISA resource name specifies the resource to be opened. The VISA resource name control also specifies the session and class.

cbool

[Read]

Select the read or write VISA function.

True : Read

False : Write

cdbl

[Set Limit Voltage]

<Limit voltage setting>

+ Limit voltage setting

range : 0.0005 to 16.1000V

resolution : 0.0005V

- Limit voltage setting

range : - 16.1000 to -0.0005V

resolution : 0.0005V

cbool

Output

Select the voltage output.

True : + Voltage output

False : - Voltage output

cerrcodeclst

Error IN[Error IN]

The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.

cu16

Terminator

Select terminator for RS-232 remote control to match the instument's terminator.

Select terminator "LF" for USB and LAN remote control.

0 : LF (Line Feed)

1 : CR (Carriage Return)

ivsrn

CopyVISAsession[CopyVISAsession]

Displays VISA resource name that specifies the resource to be opened.

istr

[Query Limit Voltage]

Displays the data received from the device

ierrcodeclst

Error OUT[Error OUT]

The error out cluster passes error or warning information out of a VI to be used by other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.


Block Diagram

NF LP6016-01 dvr_LMV.vi

NF LP6016-01 dvr_LMV.vi

NF LP6016-01 dvr_LMV.vi

NF LP6016-01 dvr_LMV.vi


NF LP6016-01 dvr_OMD.vi

Sets and queries the output mode


Connector Pane

NF LP6016-01 dvr_OMD.vi


Front Panel

NF LP6016-01 dvr_OMD.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

VISA resource name specifies the resource to be opened. The VISA resource name control also specifies the session and class.

cbool

[Read]

Select the read or write VISA function.

True : Read

False : Write

ci32

[Set Output mode]

<Output mode>

0 : Independent. Independently control each output's ON/OFF.

1 : Coupled. Control both output's ON/OFF by turning on/off each output.

cerrcodeclst

Error IN[Error IN]

The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.

cu16

Terminator

Select terminator for RS-232 remote control to match the instument's terminator.

Select terminator "LF" for USB and LAN remote control.

0 : LF (Line Feed)

1 : CR (Carriage Return)

ivsrn

CopyVISAsession[CopyVISAsession]

Displays VISA resource name that specifies the resource to be opened.

istr

[Query Output mode]

Displays the state received from the device.

ierrcodeclst

Error OUT[Error OUT]

The error out cluster passes error or warning information out of a VI to be used by other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.


Block Diagram

NF LP6016-01 dvr_OMD.vi

NF LP6016-01 dvr_OMD.vi

NF LP6016-01 dvr_OMD.vi

NF LP6016-01 dvr_OMD.vi


NF LP6016-01 dvr_POS.vi

Sets and queries the voltage output setting at startup.


Connector Pane

NF LP6016-01 dvr_POS.vi


Front Panel

NF LP6016-01 dvr_POS.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

VISA resource name specifies the resource to be opened. The VISA resource name control also specifies the session and class.

cbool

[Read]

Select the read or write VISA function.

True : Read

False : Write

ci32

[Set Power on state]

<Set output state at startup>

0(OFF) : Both voltage outputs are off.

1(ON) : Both voltage outputs are on.

2(LAST SET) : At startup, both outputs are the same as last operation.

cerrcodeclst

Error IN[Error IN]

The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.

cu16

Terminator

Select terminator for RS-232 remote control to match the instument's terminator.

Select terminator "LF" for USB and LAN remote control.

0 : LF (Line Feed)

1 : CR (Carriage Return)

ivsrn

CopyVISAsession[CopyVISAsession]

Displays VISA resource name that specifies the resource to be opened.

istr

[Query Power on state]

Displays the text received from the device

ierrcodeclst

Error OUT[Error OUT]

The error out cluster passes error or warning information out of a VI to be used by other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.


Block Diagram

NF LP6016-01 dvr_POS.vi

NF LP6016-01 dvr_POS.vi

NF LP6016-01 dvr_POS.vi

NF LP6016-01 dvr_POS.vi


NF LP6016-01 dvr_VMD.vi

Sets and queries the voltage setting mode.


Connector Pane

NF LP6016-01 dvr_VMD.vi


Front Panel

NF LP6016-01 dvr_VMD.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

VISA resource name specifies the resource to be opened. The VISA resource name control also specifies the session and class.

cbool

[Read]

Select the read or write VISA function.

True : Read

False : Write

ci32

[Set Voltage mode]

<Voltage mode>

0 : Independent. The positive and negative output voltages can be set independently.

1 : Tracking. The positive and negative output voltages can be set symmetrically so that the absolute values of them match.

cerrcodeclst

Error IN[Error IN]

The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.

cu16

Terminator

Select terminator for RS-232 remote control to match the instument's terminator.

Select terminator "LF" for USB and LAN remote control.

0 : LF (Line Feed)

1 : CR (Carriage Return)

ivsrn

CopyVISAsession[CopyVISAsession]

displays VISA resource name that specifies the resource to be opened.

istr

[Query Voltage mode]

displays the state received from the device

ierrcodeclst

Error OUT[Error OUT]

The error out cluster passes error or warning information out of a VI to be used by other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.


Block Diagram

NF LP6016-01 dvr_VMD.vi

NF LP6016-01 dvr_VMD.vi

NF LP6016-01 dvr_VMD.vi

NF LP6016-01 dvr_VMD.vi


NF LP6016-01 dvr_VLT.vi

Sets and queries the output voltage.


Connector Pane

NF LP6016-01 dvr_VLT.vi


Front Panel

NF LP6016-01 dvr_VLT.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

VISA resource name specifies the resource to be opened. The VISA resource name control also specifies the session and class.

cbool

[Read]

Select the read or write VISA function.

True : Read

False : Write

cdbl

[Set Output voltage]

<Voltage setting>

+ Voltage setting

range : 0.0000 to 16.1000V

resolution : 0.0005V

- Voltage setting

range : - 16.1000 to 0.0000V

resolution : 0.0005V

cbool

Output

Select the voltage output.

True : + Voltage output

False : - Voltage output

cerrcodeclst

Error IN[Error IN]

The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.

cu16

Terminator

Select terminator for RS-232 remote control to match the instument's terminator.

Select terminator "LF" for USB and LAN remote control.

0 : LF (Line Feed)

1 : CR (Carriage Return)

ivsrn

CopyVISAsession[CopyVISAsession]

Display VISA resource name that specifies the resource to be opened.

istr

[Query Output voltage]

Displays the text received from the device

ierrcodeclst

Error OUT[Error OUT]

The error out cluster passes error or warning information out of a VI to be used by other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.


Block Diagram

NF LP6016-01 dvr_VLT.vi

NF LP6016-01 dvr_VLT.vi

NF LP6016-01 dvr_VLT.vi

NF LP6016-01 dvr_VLT.vi


NF LP6016-01 dvr_GTL.vi

Switches from remote control to local control.


Connector Pane

NF LP6016-01 dvr_GTL.vi


Front Panel

NF LP6016-01 dvr_GTL.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

VISA resource name specifies the resource to be opened. The VISA resource name control also specifies the session and class.

cerrcodeclst

Error IN[Error IN]

The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.

cu16

Terminator

Select terminator for RS-232 remote control to match the instument's terminator.

Select terminator "LF" for USB and LAN remote control.

0 : LF (Line Feed)

1 : CR (Carriage Return)

ivsrn

CopyVISAsession[CopyVISAsession]

Displays VISA resource name that specifies the resource to be opened.

ierrcodeclst

Error OUT[Error OUT]

The error out cluster passes error or warning information out of a VI to be used by other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.


Block Diagram

NF LP6016-01 dvr_GTL.vi

NF LP6016-01 dvr_GTL.vi

NF LP6016-01 dvr_GTL.vi


NF LP6016-01 dvr_LBD.vi

Sets and queries the LCD's brightness.


Connector Pane

NF LP6016-01 dvr_LBD.vi


Front Panel

NF LP6016-01 dvr_LBD.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

VISA resource name specifies the resource to be opened. The VISA resource name control also specifies the session and class.

cbool

[Read]

Select the read or write VISA function.

True : Read

False : Write

ci32

[Set LCD brightness]

<LCD brightness>

range 0 to 3 (integer) : The brightness increasess as the value increases.

cerrcodeclst

Error IN[Error IN]

The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.

cu16

Terminator

Select terminator for RS-232 remote control to match the instument's terminator.

Select terminator "LF" for USB and LAN remote control.

0 : LF (Line Feed)

1 : CR (Carriage Return)

ivsrn

CopyVISAsession[CopyVISAsession]

Displays VISA resource name that specifies the resource to be opened.

istr

[Query LCD brightness]

Displays the text received from the device.

ierrcodeclst

Error OUT[Error OUT]

The error out cluster passes error or warning information out of a VI to be used by other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.


Block Diagram

NF LP6016-01 dvr_LBD.vi

NF LP6016-01 dvr_LBD.vi

NF LP6016-01 dvr_LBD.vi

NF LP6016-01 dvr_LBD.vi


NF LP6016-01 dvr_LCD.vi

Sets and queries the LCD's contrast.


Connector Pane

NF LP6016-01 dvr_LCD.vi


Front Panel

NF LP6016-01 dvr_LCD.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

VISA resource name specifies the resource to be opened. The VISA resource name control also specifies the session and class.

cbool

[Read]

Select the read or write VISA function.

True : Read

False : Write

ci32

[Set LCD contrast]

<LCD contrast>

range 0 to 7 (integer) : The contrast increases as the value increases.

cerrcodeclst

Error IN[Error IN]

The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.

cu16

Terminator

Select terminator for RS-232 remote control to match the instument's terminator.

Select terminator "LF" for USB and LAN remote control.

0 : LF (Line Feed)

1 : CR (Carriage Return)

ivsrn

CopyVISAsession[CopyVISAsession]

Displays VISA resource name that specifies the resource to be opened.

istr

[Query LCD contrast]

Displays the text data received from the device.

ierrcodeclst

Error OUT[Error OUT]

The error out cluster passes error or warning information out of a VI to be used by other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.


Block Diagram

NF LP6016-01 dvr_LCD.vi

NF LP6016-01 dvr_LCD.vi

NF LP6016-01 dvr_LCD.vi

NF LP6016-01 dvr_LCD.vi


NF LP6016-01 dvr_PST.vi

Queries the abnormal state.


Connector Pane

NF LP6016-01 dvr_PST.vi


Front Panel

NF LP6016-01 dvr_PST.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

VISA resource name specifies the resource to be opened. The VISA resource name control also specifies the session and class.

cerrcodeclst

Error IN[Error IN]

The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.

cu16

Terminator

Select terminator for RS-232 remote control to match the instument's terminator.

Select terminator "LF" for USB and LAN remote control.

0 : LF (Line Feed)

1 : CR (Carriage Return)

ivsrn

CopyVISAsession[CopyVISAsession]

Displays VISA resource name that specifies the resource to be opened.

istr

[Query abnormal state]

<abnormal state>

0 to 63 (NR1)

Each state is weighted as follows and received value is sum of them.

1: The positive output current exceeds the rating and overcurrent protection is working. (E102)

2: The negative output current exceeds the rating and overcurrent protection is working. (E103)

4: Overheat protection is working. (E104)

8: Calibration data are broken. (E303)

16: Setting data are broken. (E304, E305)

32: Hardware error (E901, E902, E903)

ierrcodeclst

Error OUT[Error OUT]

The error out cluster passes error or warning information out of a VI to be used by other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.


Block Diagram

NF LP6016-01 dvr_PST.vi

NF LP6016-01 dvr_PST.vi

NF LP6016-01 dvr_PST.vi


NF LP6016-01 dvr_SYSTem_ERRor.vi

Queries the oldest error in the error queue.


Connector Pane

NF LP6016-01 dvr_SYSTem_ERRor.vi


Front Panel

NF LP6016-01 dvr_SYSTem_ERRor.vi


Controls and Indicators

cvsrn

VISAsession

VISA resource name specifies the resource to be opened. The VISA resource name control also specifies the session and class.

cerrcodeclst

Error IN[Error IN]

The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.

cu16

Terminator

Select terminator for RS-232 remote control to match the instument's terminator.

Select terminator "LF" for USB and LAN remote control.

0 : LF (Line Feed)

1 : CR (Carriage Return)

ii32

ErrorNo[ErrorNo]

Displays the error number.

istr

Error

Displays the error message.

ivsrn

CopyVISAsession

Displays VISA resource name that specifies the resource to be opened.

ierrcodeclst

Error OUT[Error OUT]

The error out cluster passes error or warning information out of a VI to be used by other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.


Block Diagram

NF LP6016-01 dvr_SYSTem_ERRor.vi

NF LP6016-01 dvr_SYSTem_ERRor.vi

NF LP6016-01 dvr_SYSTem_ERRor.vi


NF LP6016-01 dvr_EQC.vi

Clears the entire error queue.


Connector Pane

NF LP6016-01 dvr_EQC.vi


Front Panel

NF LP6016-01 dvr_EQC.vi


Controls and Indicators

cvsrn

VISAsession

VISA resource name specifies the resource to be opened. The VISA resource name control also specifies the session and class.

cerrcodeclst

Error IN[Error IN]

The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.

cu16

Terminator

Select terminator for RS-232 remote control to match the instument's terminator.

Select terminator "LF" for USB and LAN remote control.

0 : LF (Line Feed)

1 : CR (Carriage Return)

ivsrn

CopyVISAsession

Displays VISA resource name that specifies the resource to be opened.

ierrcodeclst

Error OUT[Error OUT]

The error out cluster passes error or warning information out of a VI to be used by other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.


Block Diagram

NF LP6016-01 dvr_EQC.vi

NF LP6016-01 dvr_EQC.vi


NF LP6016-01 idn.vi

Queries the product information.


Connector Pane

NF LP6016-01 idn.vi


Front Panel

NF LP6016-01 idn.vi


Controls and Indicators

cvsrn

VISAsession

VISA resource name specifies the resource to be opened. The VISA resource name control also specifies the session and class.

cerrcodeclst

Error IN[Error IN]

The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.

cu16

Terminator

Select terminator for RS-232 remote control to match the instument's terminator.

Select terminator "LF" for USB and LAN remote control.

0 : LF (Line Feed)

1 : CR (Carriage Return)

ivsrn

CopyVISAsession

Displays VISA resource name that specifies the resource to be opened.

istr

Query Product information

<Product informatnion>

Vendor name (NF Corporation)

Model name (LP6016-01)

Serial number

Firmware version

ierrcodeclst

Error OUT[Error OUT]

The error out cluster passes error or warning information out of a VI to be used by other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.


Block Diagram

NF LP6016-01 idn.vi

NF LP6016-01 idn.vi

NF LP6016-01 idn.vi


NF LP6016-01 Reset.vi

Initializes almost all of settings of LP6016-01.

This VI is the same function as "initialize" of the panel operation.

*this process can not be executed when output voltage is on.


Connector Pane

NF LP6016-01 Reset.vi


Front Panel

NF LP6016-01 Reset.vi


Controls and Indicators

cvsrn

VISAsession

VISA resource name specifies the resource to be opened. The VISA resource name control also specifies the session and class.

cerrcodeclst

Error IN[Error IN]

The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.

cu16

Terminator

Select terminator for RS-232 remote control to match the instument's terminator.

Select terminator "LF" for USB and LAN remote control.

0 : LF (Line Feed)

1 : CR (Carriage Return)

ivsrn

CopyVISAsession

Displays VISA resource name that specifies the resource to be opened.

ierrcodeclst

Error OUT[Error OUT]

The error out cluster passes error or warning information out of a VI to be used by other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.


Block Diagram

NF LP6016-01 Reset.vi

NF LP6016-01 Reset.vi

NF LP6016-01 Reset.vi


NF LP6016-01 Revision Query.vi

Reads the firmware version.


Connector Pane

NF LP6016-01 Revision Query.vi


Front Panel

NF LP6016-01 Revision Query.vi


Controls and Indicators

cvsrn

VISAsession

VISA resource name specifies the resource to be opened. The VISA resource name control also specifies the session and class.

cerrcodeclst

Error IN[Error IN]

The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.

cu16

Terminator

Select terminator for RS-232 remote control to match the instument's terminator.

Select terminator "LF" for USB and LAN remote control.

0 : LF (Line Feed)

1 : CR (Carriage Return)

ivsrn

CopyVISAsession

Displays VISA resource name that specifies the resource to be opened.

istr

Instrument firmware revision

Displays firmware version.

ierrcodeclst

Error OUT[Error OUT]

The error out cluster passes error or warning information out of a VI to be used by other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.


Block Diagram

NF LP6016-01 Revision Query.vi

NF LP6016-01 Revision Query.vi


NF LP6016-01 Close.vi

Closes a device session or event object specified by VISA resource name.


Connector Pane

NF LP6016-01 Close.vi


Front Panel

NF LP6016-01 Close.vi


Controls and Indicators

cvsrn

VISAsession

VISA resource name specifies the resource to be opened. The VISA resource name control also specifies the session and class.

cerrcodeclst

Error IN[Error IN]

The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.

ivsrn

CopyVISAsession

Displays VISA resource name that specifies the resource to be opened.

ierrcodeclst

Error OUT[Error OUT]

The error out cluster passes error or warning information out of a VI to be used by other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.


Block Diagram

NF LP6016-01 Close.vi

NF LP6016-01 Close.vi


NF LP6016-01 Initialize.vi

Opens a VISA session to communicate with LP6016-01 and initializes it.


Connector Pane

NF LP6016-01 Initialize.vi


Front Panel

NF LP6016-01 Initialize.vi


Controls and Indicators

cvsrn

VISAsession

VISA resource name specifies the resource to be opened. The VISA resource name control also specifies the session and class.

cbool

isReset

Resets the instrument and defaults the setup.

cbool

isIdQuery

Queries the product information.

cerrcodeclst

Error IN[Error IN]

The error in cluster can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.

cbool

RS-232 enable

Enables RS-232 parameters.

Select this check box for RS-232 remote control.

cnclst

RS-232 param

Settings for RS-232 remote control.

ivsrn

CopyVISAsession

Displays VISA resource name that specifies the resource to be opened.

istr

Product Information

<Product informatnion>

Vendor name (NF Corporation)

Model name (LP6016-01)

Serial number

Firmware version

ierrcodeclst

Error OUT[Error OUT]

The error out cluster passes error or warning information out of a VI to be used by other VIs.

The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.

ii16

Terminator

The terminator for remote control.

0 : LF(Line Feed)

1 : CR(Carriage Return)


Block Diagram

NF LP6016-01 Initialize.vi

NF LP6016-01 Initialize.vi

NF LP6016-01 Initialize.vi

NF LP6016-01 Initialize.vi

NF LP6016-01 Initialize.vi

NF LP6016-01 Initialize.vi

NF LP6016-01 Initialize.vi

NF LP6016-01 Initialize.vi