Frequency Response Analyzer
Frequency Response Analyzer
FRA5087/FRA5097

Frequency range 0.1mHz to 10MHz / 15MHz
From ultra low frequency to high frequency.
High density measurements of up to 20,000 points at one sweep are possible.
Logarithmic equal interval setting and auto-magnification in sections where values greatly change are possible. Resolution is 0.1mHz.

FRA5087 : 0.1mH to 10MHz Higher than the conventional 2.2MHz model!
FRA5097 : 0.1mH to 15MHz

Gain accuracy : ±0.05 dB , Phase accuracy : ±0.3°
Digital Fourier transforms and a self calibration function assure that measurements will always be highly accurate.

Dynamic range : 140dB
Auto ranging which optimizes the measurement range at every measurement point and a high resolution A/D converter secure a wider dynamic range. Measurement is secured if a great change occurs during measurement.

Isolation
Oscillator output 2-channel and analysis inputs are isolated from the cabinet by 250Vrms. In this way, the instrument can be protected from damage by an erroneous signal connection.

Auto ranging
Input range is switched automatically according to the input signal level, so setup of voltage sensitivity is not necessary for the frequency response analyzer.

Various graphic outputs
Bode, Nyquist, Nicols, and Cole-Cole plots can be displayed. Following measurement, interconversion is also available.

Impedance display function(optional for FRA5087)
Impedance can be accurately measured and displayed. Moreover, open-short correction, maximum and minimum value displays, and screen image storage can be done.

FRA5087 : Optional (PA-001-1231)
FRA5097 : Standard

Excellent functions are built-in
Basic Setup Key
A basic setup screen is displayed simply by pressing the basic setup key. The upper lower limits, amplitude, and number of integrations for measuring frequency (sweep) can be set on one screen. The conventional model's nuisance of setting each item by switching the screen can thus be avoided.

Battery backup
The contents of the setup and measured data stored in the memory before turning off power are held if power is turned off.

GPIB and USB equipped
Measuring conditions can be set via an external personal computer and measured data can be read out to it via GPIB and USB.

Easy saving and reading by USB memory
USB
Measured data can be stored and loaded into a USB memory device. Furthermore, the following functions are available.

SCREEN COPY
A screen can be output to the USB memory and printer by the press of a key.

CONDITION
Setup conditions can be saved into and loaded from the USB memory by the press of a key.

File read out software
Data stored in the USB memory can be read out to a personal computer for graphic display and saving in a CSV format.

This software can be downloaded from the NF Web site.

Built-in printer
A printer for outputting hard copies of on-screen images onto thermosensitive paper is built-in, which makes saving measurements and creating reports convenient.